- Circuit Breakers[10]
- Contactors[10]
- Relays[10]
- Other Switches[3]
- Cable Ties[1]
- Cable Clips[1]
- Cable Sleeves[1]
- Insulation Materials & Elements[1]
- Other Wiring Accessories[1]
- Wiring Ducts[2]
- Terminal Blocks[3]
- Other Connectors & Terminals[2]
- Connectors[2]
- Fire Alarm[2]
- Multimeters[4]
- Energy Meters[7]
- Current Meters[2]
- Fuses[3]
- Fuse Components[3]
- Micro Switches[4]
- Limit Switches[3]
- Electrical Plugs & Sockets[7]
- Electronic & Instrument Enclosures[4]
- Power Distribution Equipment[3]
- Thyristors[2]
- Rectifiers[1]
- Power Accessories[4]
- Contact Person : Mr. guo peter
- Company Name : Wenzhou Jerdin Electric Co., Ltd.
- Tel : 86-577-62728800
- Fax : 86-577-62738811
- Address : Zhejiang,WENZHOU,#36,Yiheng Road,Xinguang Industrial,Liushi,Wenzhou,China
- Country/Region : China
3UA thermal overload relay
3UA thermal overload relay can be used with 3TF/3TB contactor,also can be installed as single unit.
3UA thermal relay series are suitable for overload and phase-failure protection of ACmotors with frequency of 50/60Hz,voltage up to 690-1000V,current up to 0.1-630A under 8-hours duty or uninterrupted duty. It is used to protect AC three-phase asynchronous motor against overload and open-phase. The current setting value can be regulated and the setting current values of many thermal elements are intercrossing overleapping arrangement, for easy selecting by the customers from -25 to +55 air temperature as the products have temperature compensating. The relays have the test push-button for breaking NC contacts, the operating indication and free trip characteristics. The items conform to IEC60947-5.
Type | Rated operating current (A) | Rated insulation voltage (V) | Current Setting range (A) |
3UA50 | 12.5 | 660 | 0.1~0.16,0.16~0.25,0.25~0.4,0.32~0.63,0.63~0.1,0.8~1.25,1~1.6,1.25~2,1.6~2.5,2~3.2,2.5~4,3.2~5,4~6.3,5~8,6.3~10,8~12.5 |
3UA52 | 25 | 660 | 0.1~0.16,0.16~0.25,0.25~0.4,0.32~0.63,1.63~1,0.8~1.25,1~1.6,1.25~2,1.6~2.5,2~3.2,2.5~4,3.2~5,4~6.3,5~8,6.3~10,8~12.5,10~16,12.5~20,16~25 |
3UA54 | 32 | 660 | 4~6.3,6.3~10,10~16,12.5~20,16~25,20~32 |
3UA58 | 80 | 660 | 16~25,20~32,25~40,32~50,40~57,50~63,57~70,63~80 |
3UA59 | 63 | 660 | 0.1~0.16,0.16~0.25,0.25~0.4,0.32~0.63,0.63~0.1,0.8~1.25,1~1.6,1.25~2,1.6~2.5,2~3.2,2.5~4,3.2~5,4~6.3,5~8,6.3~10,8~12.5,10~16,12.5~20,16~25,20~32,25~40,32~45,40~57,50~63 |
3UA62 | 180 | 660 | 55~80, 63~90, 80~110, 90~120, 110~135, 120~150, 135~160, 150~180 |
3UA66 | 400 | 1000 | 80~125, 125~200, 180~250, 200~320, 250~400 |
3UA68 | 630 | 1000 | 320~500, 400~630 |
3UA thermal overload relay